Tubulin (HiLyte 488TM dye labeled; porcine, micro-injctn)
貨號 | TL488M-A | 售價(元) | 5271 |
規(guī)格 | 5 x 20 μg | CAS號 |
- 產品簡介
- 相關產品
HiLyte Fluor? 488 labeled microtubules formed from HiLyte Fluor? 488 labeled tubulin.
Product Uses Include:
Laser based applications
Monitoring microtubule dynamcs in living cells
Speckle microscopy
Formation of fluorescent microtubules
Microscopy studies of MAP and microtubule associated motor activities
Nanotechnology
Material:
Porcine brain tubulin (>99% pure, see Cat. # T240) has been modified to contain covalently linked HiLyte Fluor? 488 (HiLyte Fluor is a trademark of Anaspec Inc, CA) at random surface lysines. An activated ester of HiLyte Fluor? 488 was used to label the protein. Labeling stoichiometry was determined by spectroscopic measurement of protein and dye concentrations (dye extinction coefficient when protein bound is 76,000M-1cm-1). Final labeling stoichiometry is 1-2 dyes per tubulin heterodimer. HiLyte Fluor? 488 labeled tubulin can be detected using a filter set of 440-460 nm excitation and 500-520 emission. HiLyte Fluor? 488 tubulin is in a versatile, stable and easily shipped format. It is ready for micro-injection or in vitro polymerization. Cytoskeleton, Inc. also offers AMCA (Cat. # TL440M), rhodamine (Cat. # TL590M), X-rhodamine (Cat. # TL620M) and HiLyte Fluor? 647 (Cat. # TL670M) labeled tubulins of the same quality.
Purity:
The protein purity of the tubulin used for labeling is determined by scanning densitometry of Coomassie Blue stained protein on a 4-20% polyacrylamide gel. The protein used for TL488M is >99% pure tubulin (Figure 1 A). Labeled protein is run on an SDS gel and photographed under UV light. Any unincorporated HiLyte Fluor? 488 dye would be visible in the dye front. No fluorescence is detected in the dye front, indicating that no free dye is present in the final product (Figure 1 B).
Figure 1: HiLyte Fluor? 488 tubulin protein purity determination. A 50 μg sample of unlabeled tubulin protein was separated by electrophoresis in a 4-20% SDS-PAGE system and stained with Coomassie Blue (A). Protein quantitation was performed using the Precision Red Protein Assay Reagent (Cat. # ADV02). 20 μg of the same protein sample was run in a 4-20% SDS-PAGE system and photographed directly under UV illumination (B).
Biological Activity:
The biological activity of HiLyte Fluor? 488 tubulin is assessed by a tubulin polymerization assay. To pass quality control, a 5 mg/ml solution of AMCA labeled tubulin in G-PEM plus 5% glycerol must polymerize to >85%. This is comparable to unlabeled tubulin under identical conditions.